Video6 min·Published Jun 2023Published over 3 years ago

Thoracoscopic PDA Ligation and Lung Biopsy in a 2kg Infant by Dr. Steven Rothenberg

With Dr. Steven Rothenberg

Chapter 1 of 5 · Surgical Management

Port placement

Patient positioning and port placement

Cued at 0:20 · stops at 0:42 · press play

Try
Intelligent Search· scoped to patent ductus arteriosus · not medical adviceSearch the whole library →

What the experts said

19 expert statements
The patient is a 2 kg infant undergoing thoracoscopic PDA ligation.
ClinicalSteven Rothenberg0:02
Modified prone position with left side elevated approximately 30 degrees is used for thoracoscopic PDA ligation.
ClinicalSteven Rothenberg0:20
Port placement includes a 4mm scope slightly behind and above the scapula tip, with 3mm and 5mm working ports.
ClinicalSteven Rothenberg0:50
Simple insufflation is used to collapse the lung; single lung ventilation is not required, although it can be carried out in larger patients.
ClinicalSteven Rothenberg1:20
A 3mm port is initially placed in the posterior axillary line in approximately the fifth intercostal space, later changed to 5mm for clip placement.
ClinicalSteven Rothenberg1:50
It is important not to use monopolar cautery near the ductus because of the risk of injuring the recurrent laryngeal nerve.
ClinicalSteven Rothenberg2:40
Creating a pleural flap over the mid portion of the aorta helps safely retract the vagus and recurrent laryngeal nerves out of the way.
ClinicalSteven Rothenberg3:20
In this case, the ductus is large, approximately 2/3 the diameter of the aorta.
ClinicalSteven Rothenberg4:00
Careful blunt dissection is used to dissect behind the ductus to avoid injuring the recurrent laryngeal nerve or tearing the ductus.
ClinicalSteven Rothenberg4:20
Gentle spreading with the 3mm vessel sealer is an excellent way to achieve adequate mobilization.
OpinionSteven Rothenberg4:40
It is generally recommended to spread in the direction of the ductus to eliminate the risk of tearing.
ClinicalSteven Rothenberg5:10
Test clamping of the ductus is performed with a distal pulse oximeter on the foot to ensure the correct structure is being occluded.
ClinicalSteven Rothenberg5:50
It is very important to have proximal and distal monitoring during PDA ligation.
ClinicalSteven Rothenberg6:10
Care must be taken to ensure tissue is far enough in the stapler so the staple line reaches across the entire resected specimen.
ClinicalSteven Rothenberg6:24
No chest drain was left because there was no air leak at the end of the procedure.
ClinicalSteven Rothenberg6:24
It is important to deploy the clip into the clip applier before placing it onto the duct, as deploying while already around the duct can force tissue away.
ClinicalSteven Rothenberg6:35
A single 5mm clip achieved complete occlusion of the ductus.
ClinicalSteven Rothenberg7:00
The patient had evidence of interstitial lung disease on CT scan, prompting a lung biopsy request from the pulmonologist.
ClinicalSteven Rothenberg7:10
A 5mm stapler fits appropriately for the size of a 2 kg infant for lung biopsy.
ClinicalSteven Rothenberg7:50
GCMD Library — educational content from recorded physician discussions, not medical advice.