The patient is a 1 day old infant who had a prenatal diagnosis of duodenal atresia
Clinical0:00
Port placements consist of a 4 millimeter scope in the umbilicus, a 3 millimeter port in the left mid quadrant, and a 3 millimeter stab wound in the right mid quadrant, triangulated towards the right upper quadrant
Clinical0:30
The 3 millimeter sealer is an excellent dissecting device and can be used in safe energy in close approximation to both the gallbladder and the small bowel
Opinion1:00
A transabdominal stitch using a 30 Prolene on an RB1 needle is placed through the anterior abdominal wall in the right upper quadrant to retract the gallbladder superiorly
Clinical2:00
The child is malrotated with a complete duodenal atresia
Clinical2:30
The bowel is run from proximal to distally to ensure that there are no further Ladd's bands and to completely de-rotate the bowel
Clinical3:00
A Meckel's diverticulum is found in the distal ileum during the procedure
Clinical3:30
All of the small bowel is placed on the patient's right and the large bowel on the patient's left
Clinical4:00
Widening the mesenteric base should diminish the chance of volvulus in the future
Clinical4:30
A transverse enterotomy is made at the most dependent portion of the dilated proximal segment
Clinical5:00
The enterotomy in the distal segment is longitudinal
Clinical5:30
There is increased smoke and debris from using electrocautery compared to the 3 millimeter sealer
Clinical6:00
A transabdominal stitch aligns the two sides of the bowel to perform the side to side anastomosis
Clinical6:30
A pre-cut Vicryl suture approximately 10 to 12 centimeters in length is used to run the back row of the anastomosis
Clinical7:00
In some cases, the distal duodenal segment is more fixed to the retroperitoneum, making this part of the procedure more difficult, but the same technique is used with excellent result
Clinical8:00
The surgeon prefers running suture over interrupted suture as it works extremely well and is more efficient
Opinion9:00
The entire procedure took approximately 50 minutes
Clinical9:30
Approximately 10% of patients undergoing laparoscopic repair of duodenal atresia have malrotation
Epidemiological10:00
The patient is a 2.8 kg child
Clinical10:00
A nasogastric tube is left to suction for approximately 3 to 4 days, and in most cases feeds are started by the 5th day
Clinical10:30
This child started eating on the 5th postoperative day and was on full feeds by the 8th postoperative day
Clinical11:00
The base of the Meckel's diverticulum could adequately be divided without compromising the lumen of the bowel, so a decision was made to remove it using the 5 millimeter stapler
Clinical12:00
The left quadrant 3 millimeter port was changed to a 5 millimeter port to allow insertion of the endoscopic stapler
Clinical13:00
Because of the malrotation, the appendix was also removed
Clinical13:30
The child was discharged to home on the 10th postoperative day