Video6 min·Published May 2026

PDA ligation narrated

With Dr. Steve Rothenberg

Chapter 4 of 4 · Surgical Management

Biopsy & closure

Lung biopsy and closure

Cued at 7:50 · stops at 8:35 · press play

Try
Intelligent Search· scoped to patent ductus arteriosus · not medical adviceSearch the whole library →

What the experts said

23 expert statements
The infant undergoing thoracoscopic PDA ligation weighs 2 kg.
Clinical0:02
The patient is placed in a modified prone position with the left side elevated approximately 30 degrees for thoracoscopic PDA ligation.
Clinical0:20
Port placement includes a 4 mm scope slightly behind and above the scapula tip, and 3 mm and 5 mm working ports.
Clinical0:50
Simple insufflation is used to collapse the lung; single lung ventilation is not required, although it can be used in larger patients.
Clinical1:20
A 3 mm port is initially placed in the posterior axillary line in approximately the fifth intercostal space to aid dissection, later changed to a 5 mm port for clip placement.
Clinical1:50
It is important not to use monopolar cautery near the ductus because of the risk of injuring the recurrent laryngeal nerve.
Clinical2:30
Creating a pleural flap over the mid portion of the aorta helps safely retract the vagus and recurrent laryngeal nerves out of the way.
Clinical3:10
In this case, the ductus is large, approximately two-thirds the diameter of the aorta.
Clinical3:50
Careful blunt dissection is used to dissect behind the ductus to avoid injuring the recurrent laryngeal nerve or tearing the ductus.
Clinical4:10
Gentle spreading with the 3 mm vessel sealer is an excellent way to achieve adequate mobilization of the ductus.
Opinion4:30
It is generally recommended to spread in the direction of the ductus to eliminate the risk of tearing it.
Clinical4:55
Test clamping of the ductus is performed with a distal pulse oximeter on the foot to ensure the correct structure is being occluded.
Clinical5:20
It is very important to have proximal and distal monitoring during PDA ligation.
Clinical5:40
A single 5 mm endoclip is placed on the ductus after the 3 mm trocar is changed to a 5 mm trocar.
Clinical5:50
It is important to deploy the clip into the clip applier before placing it onto the duct, as deploying while already around the duct can force the tissue away.
Clinical6:05
The clip application resulted in complete occlusion of the ductus.
Clinical6:20
No chest drain was left because there was no air leak at the end of the procedure.
Clinical6:24
All incisions were closed in layers with absorbable suture.
Clinical6:24
The patient had evidence of interstitial lung disease on CT scan, and the pulmonologist requested a lung biopsy for better evaluation.
Clinical6:30
A 5 mm stapler is appropriate in size for a 2 kg infant for performing a wedge lung biopsy.
Clinical7:00
Care must be taken to ensure tissue is far enough into the stapler so the staple line reaches across the entire line of the resected specimen.
Clinical7:20
A single firing of the stapler is all that is needed for the wedge biopsy.
Clinical7:40
The lung biopsy specimen is removed through the 5 mm port site without difficulty.
Clinical7:50