Chapter 2 of 3
QI interventions
Quality Improvement Interventions and Safety Considerations
Cued at 2:11 · press play
Expert statements on this page
No expert statements were drawn from this page.
Host summaries · secondary, not cited in answers
Educational content from recorded physician discussions — not medical advice. Talk to your (or your child's) care team about your situation.
More from this expert
Dr. Alexander J. TowbinPodcast
Customer Service in Radiology: Satisfying Your Patients and Referrers
Alexander J. Towbin · Published Nov 2026
Video
Measuring Radiology's Impact: Core Concepts for Tracking Patient-Oriented Outcomes & High-Value Care
Alexander J. Towbin · 10 min · Published Sep 2026
Video
Five Minutes in Healthcare Featuring Dr. Alexander Towbin
Alexander J. Towbin · 11 min · Published Jul 2020
Video
44. Assessment of Pediatric Liver Tumors - Part 1 . By Prof. Dr. Alexander Towbin
Alexander J. Towbin · 49 min · Published May 2020
Video
Get to Know Your Radiologist Dr. Towbin
Alexander J. Towbin · 6 min · Published Mar 2017
What the experts said
The baseline mean turnaround time for reading emergency department radiographic studies was approximately 20 minutes, which is among the best in the world.
Despite excellent mean turnaround time, variability was high, with some studies read in under 10 minutes and others taking 40-50 minutes.
Emergency department requires predictable turnaround times to manage patient flow and prioritize care for patients who need it most urgently.
The quality improvement team included members from emergency department, radiology department, and the Anderson Center for quality improvement.
Interventions included educating radiologists about the problem, showing them data, and explaining the impact on emergency department operations.
Daily feedback was provided to radiologists about their performance from the previous night shift.
A key concern during the improvement project was ensuring that faster reading times did not compromise diagnostic accuracy.
The target total turnaround time from X-ray order to report delivery was set at approximately one hour.
Technologists require approximately 25 minutes for ordering the study, transporting the patient to radiology, and acquiring images.
The radiologist reading time goal was set at 35 minutes (60-minute total minus 25-minute technologist time).
Radiologists in the department agreed that 35 minutes was a reasonable and safe time frame for reading emergency department studies.
Mean turnaround time decreased from approximately 20 minutes to approximately 15 minutes following the interventions.
The improvements in turnaround time have been sustained over time.
The emergency department reported noticing a difference and commented that radiology service is excellent and consistent.