Follow
Video14 min·Published Mar 2020Published over 6 years ago

Button Battery Ingestion

Chapter 3 of 6 · Fundamentals

Vascular complications

Epidemiology, pathophysiology, and vascular complications

Cued at 6:35 · stops at 7:02 · press play

Try
Intelligent Search· scoped to button battery ingestion · not medical adviceSearch the whole library →

What the experts said

18 expert statements · 10 host summaries
Button battery ingestions are becoming more frequent, with national data showing increasing numbers of emergency department visits.
EpidemiologicalDan0:01
Button batteries are ubiquitous in greeting cards, remotes, and similar devices.
ClinicalDan0:50
A ring around the edge of a circular object on X-ray indicates it is a button battery, not a quarter.
ClinicalDan1:30
Foley catheter technique may work for button battery removal when operating room access is delayed and symptom duration is short.
ClinicalDan2:10
NASPGHAN and the GI group developed guidelines for button battery management with zero input from surgeons.
GuidelineMark3:44
Guidelines mandate serial MRIs for button battery cases due to concern for vascular injury.
GuidelineMark4:10
20-25 millimeter batteries are lithium batteries that tend to be 3 volt rather than 1.5 volt.
ClinicalDan5:30
The pathophysiology is caustic injury from hydroxide ions that rapidly raise tissue pH, not mechanical erosion or electricity.
ClinicalDan5:45
Complications include esophageal perforation, stricture, tracheoesophageal fistula, and vocal cord paralysis not associated with perforation.
ClinicalDan6:10
Using trauma one system activation reduced time from door to OR from 1.5 hours to less than 30 minutes.
Clinical8:47
For minor mucosal injury on endoscopy, symptomatic follow-up without intervention is appropriate.
OpinionDan10:24
For circumferential erosions that look bad, re-scoping to look for stricture formation is recommended.
OpinionDan10:43
If patients become symptomatic after injury, esophagram can assess for narrowing or stricture.
ClinicalDan10:54
Endoscopy advantage over esophagram is ability to reassess appearance and dilate if needed.
ClinicalDan11:32
If already performing endoscopy and capable of removing battery from stomach, removal is advocated.
OpinionDan12:27
20-25 millimeter batteries are the ones of most concern.
Clinical13:01
There is evolving work in animal models using 0.25% acetic acid applied to the area of injury to neutralize it.
Clinical13:34
Acetic acid for neutralization is not something off the shelf and requires pharmacy coordination.
Clinical13:58
The number of ED visits for button battery ingestion has doubled according to Colorado study data.
Host summaryDan summarizing the discussion · not cited in answers4:41
The rate of significant complications from button batteries has increased almost sevenfold.
Host summaryDan summarizing the discussion · not cited in answers5:00
90% of serious outcomes occur with 20-25 millimeter batteries.
Host summaryDan summarizing the discussion · not cited in answers5:15
Aortoenteric fistula is the most common cause of mortality in the national data bank, accounting for 46% of mortalities.
Host summaryDan summarizing the discussion · not cited in answers6:35
Another 29% of mortalities involved some sort of vascular compromise.
Host summaryDan summarizing the discussion · not cited in answers7:00
Aortoenteric fistula can occur up to 2 weeks post-removal of the battery.
Host summaryDan summarizing the discussion · not cited in answers7:15
Authors of the Colorado paper recommend MRI after battery removal to assess potential impact on surrounding vasculature.
Host summaryDan summarizing the discussion · not cited in answers7:35
Some authors advocate scoping patients even when battery is in the stomach because patients can have significant esophageal injuries with the battery having passed on.
Host summaryDan summarizing the discussion · not cited in answers9:28
Poison.gov recommendations say you do not need to scope if the battery is in the stomach.
Host summaryMark summarizing the discussion · not cited in answers9:56
There is GI literature about removing 20 millimeter batteries from stomach because they may not pass the ileocecal valve.
Host summaryDan summarizing the discussion · not cited in answers12:50
GCMD Library — educational content from recorded physician discussions, not medical advice.