Pectus Bar Dislocation: Comparison Between Three Different Stabilization Techniques Adopted in a Single Centre

Space: StayCurrentMD Author: Luzia Toselli, Daniela Sanjurjo, Facundo Giacosa, Gaston Bellia-Munzon Published:

Author / Expert

Luzia Toselli, Daniela Sanjurjo, Facundo Giacosa, Gaston Bellia-Munzon

Topic overview

We have read with great interest the article by Donati et al. [1]. To our knowledge, this is the first study comparing different stabilization methods of pectus excavatum implants, including lateral bridges. The authors have shown a significant decrease in the implant dislocation rate as they shifted from suturing the bars to the ribs (8.8%) to using lateral stabilizers (4.8%), and finally, to lateral bridges with a 0% dislocation rate (p 