Collection
Collection by Dr. Alexander J. Towbin

Artificial Intelligence in Radiology

items total cited expert statements Updated Nov 17, 2026
Try
Intelligent Search· answers come only from this collection · not medical advice
Content of this collection items

Radiology systems should be designed to avoid automation bias and the potential decline in radiologist performance. Are the Pilots Onboard? Equipping Radiologists for Clinical Implementation of AI.

Are the Pilots Onboard? Equipping Radiologists for Clinical Implementation of AI.
The incorporation of artificial intelligence into radiological clinical workflow is on the verge of being realized. To ensure that these tools are effective, measures must be taken to educate radiologists on tool performance and failure mod
article · Nov 2026
Read →

Cohen κ comparing ResNet-50 consensus rating to ground truth was 0.76 (95% CI: 0.63, 0.89), compared to 0.49 (95% CI: 0.37, 0.61) for technologists and 0.66 (95% CI: 0.54, 0.78) for radiologists. Automatic Detection of Inadequate Pediatric Lateral Neck Radiographs of the Airway and Soft Tissues using Deep Learning

Skeletal Age Assessment1 item
Artificial Intelligence Algorithm Improves Radiologist Performance in Skeletal Age Assessment: A Prospective Multicenter Randomized Controlled Trial
Background Previous studies suggest that use of artificial intelligence (AI) algorithms as diagnostic aids may improve the quality of skeletal age assessment, though these studies lack evidence from clinical practice. Purpose To compare the
article · Nov 2026
Read →
Quality Control1 item
Automatic Detection of Inadequate Pediatric Lateral Neck Radiographs of the Airway and Soft Tissues using Deep Learning
Purpose: To develop and validate a deep learning (DL) algorithm to identify poor-quality lateral airway radiographs. Materials And Methods: A total of 1200 lateral airway radiographs obtained in emergency department patients between January
article · Nov 2026
Read →

Underrepresentation of children in public medical imaging datasets
Nature Health - In an analysis of 203 public medical imaging datasets, children are found to represent less than 2% of the overall images, leading also to disparities in algorithm performance in a...
article · Nov 2026
Read →

Are the Pilots Onboard? Equipping Radiologists for Clinical Implementation of AI.
Measures must be taken to educate radiologists on AI tool performance and failure modes.
Radiology systems should be designed to avoid automation bias and the potential decline in radiologist performance.
Artificial Intelligence Algorithm Improves Radiologist Performance in Skeletal Age Assessment: A Prospective Multicenter Randomized Controlled Trial
The mean absolute difference between radiologist skeletal age assessment and a reference panel was 5.36 months when using the AI algorithm compared with 5.95 months without AI assistance (P = .04).
Cites published research
Hand radiographs were interpreted by 93 radiologists from six centers in this prospective randomized controlled trial.
Cites published research
A total of 792 examinations were performed with the AI algorithm and 739 without the AI algorithm.
Cites published research
When using the AI algorithm, radiologists were shown the AI interpretation as part of routine clinical work and were permitted to accept or modify it.
Cites published research
The primary efficacy outcome was the mean absolute difference between the skeletal age dictated into the radiologists' signed report and the average interpretation of a panel of four radiologists not using a diagnostic aid.
Cites published research
Interpretation time was measured as a secondary outcome in the study.
Cites published research
A linear mixed-effects regression model with random center- and radiologist-level effects was used to compare the two experimental groups.
Cites published research
Automatic Detection of Inadequate Pediatric Lateral Neck Radiographs of the Airway and Soft Tissues using Deep Learning
A total of 1200 lateral airway radiographs obtained in emergency department patients between January 1, 2000, and July 1, 2019, were retrospectively queried and classified by radiologists as adequate or inadequate.
Cites published research
The training set contained 961 radiographs and the test set contained 239 radiographs.
Cites published research
The ResNet-50 deep learning classifier achieved sensitivity of 0.90 (95% CI: 0.86, 0.94), specificity of 0.82 (95% CI: 0.76, 0.90), and area under the receiver operating characteristic curve of 0.86 (95% CI: 0.81, 0.91) for detecting inadequate lateral airway radiographs.
Cites published research
Interrater agreement for technologists in classifying radiograph quality was fair with Fleiss κ of 0.36 (95% CI: 0.29, 0.43).
Cites published research
Interrater agreement for radiologists in classifying radiograph quality was moderate with Fleiss κ of 0.59 (95% CI: 0.52, 0.66).
Cites published research
Cohen κ comparing ResNet-50 consensus rating to ground truth was 0.76 (95% CI: 0.63, 0.89), compared to 0.49 (95% CI: 0.37, 0.61) for technologists and 0.66 (95% CI: 0.54, 0.78) for radiologists.
Cites published research
GCMD Library — Curated collection · summaries prepared automatically from the recordings · educational content, not medical advice
Start the course
We remember your choice for this collection.