The Nuss procedure for repair of pectus excavatum: 20 Error Traps and a culture of safety
sciencedirect.com shows its articles on its own site.
Read the article on sciencedirect.com ↗Article · Jun 2019 · 1 min read
In brief
In brief
Expert review of 20 common error traps in the Nuss procedure for pectus excavatum repair, emphasizing the operation's steep learning curve and need for systematic safety protocols. Covers preoperative planning, intraoperative technique refinements, and postoperative management strategies to prevent rare but serious complications in this widely-adopted minimally invasive chest wall reconstruction.
Written by the GCMD Library team from the article.
Publication date: Available online 25 April 2019
Source: Seminars in Pediatric Surgery
Author(s): David M. Notrica
Abstract
In 1998, Donald Nuss changed the way the world thought about the surgical repair of pectus excavatum. The new operation adheres to sound orthopedic fundaments, but has a significantly higher learning curve than other operations in pediatric surgery. Variations in pectus excavatum type, severity, symmetry and chest wall pliability bring challenges. This article will detail common error traps and ways to avoid them when performing the Nuss procedure. As recent publications have shown, an operation done more than 50,000 times across the world may bring to light infrequent but devastating outcomes that may be preventable. The critical view of safety for pectus repair is discussed, as are areas where a culture of safety could optimize results on a larger scale. We will review potential opportunities to improve outcomes by identifying error traps in the preoperative, intraoperative, and postoperative care of patients undergoing the Nuss procedure.