Short communication: effect of storage and preservation on total bacterial counts determined by automated flow cytometry in bulk tank goat milk

pubmed.ncbi.nlm.nih.gov shows its articles on its own site.

Read the article on pubmed.ncbi.nlm.nih.gov ↗

Article · Jan 2009 · 1 min read

In brief

In brief

This study evaluates how storage temperature, preservatives (azidiol vs bronopol), and sample age affect automated flow cytometry bacterial counts in bulk tank goat milk. Results show bronopol-preserved samples produce unreliable counts and should be avoided for this testing method.

Written by the GCMD Library team from the article.

Dr Luis Enrique Sanchez Sierra

This study was designed to evaluate the effects of different storage conditions on total bacterial count (TBC) determinations made in goat bulk tank milk using an automated flow cytometry method. The storage conditions tested were storage temperature (refrigeration at 4 and 10 degrees C or freezing at -20 degrees C), the use of a preservative (no preservative, NP; azidiol, AZ; or bronopol, BR), and the age of the milk samples for each analytical condition (storage times at 4 degrees C: from 0 h to 5 d for NP; and from 0 h to 22 d for AZ and BR; storage times at 10 degrees C: from 24 h to 2 d for NP and from 24 h to 22 for AZ and BR; storage times at -20 degrees C: from 24 h to 22 d for NP, AZ, and BR). Significant effects on individual bacterial count (IBC) variation were shown by the bulk tank milk sample, preservative, storage temperature, interaction preservative x storage temperature, and milk age within the interaction preservative x storage temperature. In preserved samples, the highest IBC were obtained for AZ and the lowest counts were obtained in samples preserved with BR. Because of the variation in IBC recorded in BR-preserved samples, we recommend that BR should not be used for TBC determinations using the automated flow cytometry method. The NP samples stored at 4 and 10 degrees C showed significantly higher IBC at 24 h postcollection, also invalidating these analytical conditions for TBC analyses. The practical implications of our findings are that goat milk sam

Read it at the source ↗

Try
Intelligent Search· scoped to this article · not medical adviceSearch the whole library →