Indocyanine Green Fluorescence for Intraoperative Tumor Identification During Resection of Pediatric and Adolescent Intra-Abdominal Malignancy: A Prospective Multi-Institutional Observational Study
pubmed.ncbi.nlm.nih.gov shows its articles on its own site.
Read the article on pubmed.ncbi.nlm.nih.gov ↗Article · Jun 2026 · 1 min read
In brief
In brief
Multi-institutional prospective study evaluating ICG fluorescence for real-time tumor identification during pediatric solid tumor resection found highest diagnostic accuracy in hepatic malignancies (83% sensitivity) but no improvement in margin-negative rates. Results support tumor-specific application rather than routine margin guidance.
Written by the GCMD Library team from the article.
Statements in this article
Real-time intraoperative discrimination of malignant tissue during pediatric solid-tumor resection is limited, constraining margin optimization.
Forty-three operations in 42 patients yielded 55 specimens, of which 47 (85%) were malignant.
Diagnostic performance of ICG fluorescence was highest in hepatic tumors with sensitivity 83% and positive predictive value 83%.
Diagnostic performance of ICG fluorescence was lower in adrenal and heterogeneous tumor types.
ICG avidity was not associated with improved negative margin rates (86% vs 75%, p = 0.47).
Surgeons reported intraoperative benefit in 67% of cases, most commonly improved visualization.
No ICG-related adverse events occurred.
ICG fluorescence provides reliable tumor identification in hepatic malignancies but does not correlate with margin-negative resection, indicating limited use for margin guidance.