In brief

In brief

This study validates the MilkoScan FT 6000 analyzer against reference cryoscopy for measuring freezing point in goat milk under various preservation and water-adulteration conditions. Both methods showed comparable repeatability, with MilkoScan readings averaging 1.5m°C lower than reference values.

Written by the GCMD Library team from the article.

Dr Luis Enrique Sanchez Sierra

The aim of this research was to evaluate the Milko-Scan FT 6000 (Foss Electric, Hillerød, Denmark) for determining the freezing point (FP) of goat's milk under different analytical conditions. The FP was determined in duplicate in 1,800 milk aliquots obtained from 45 bulk tank milk samples from 10 Murciano-Granadina goat herds, using the MilkoScan method and a reference thermistor cryoscopy method (Advanced Instrument Inc., Norwood, MA). Five different preservation strategies--no preservative, preservation with azidiol (0.006 or 0.018 g of sodium azide/100 mL), and preservation with bronopol (0.020 or 0.040 g/100 mL)--were then used to preserve the milk. For each preservation strategy, 8 different amounts of water were added (0, 1, 2, 3, 4, 5, 6, or 7% total volume). The results obtained with each method under these 40 analytical conditions were examined by comparison of means, comparison of the standard deviations of repeatability (s(r) and its relative value s(r)%), and a regression analysis. Under most analytical conditions, the FP was recorded as lower by the MilkoScan method, with a mean difference of 1.5 m degrees C compared with the reference method. Both methods showed similar repeatabilities (the overall s(r)% was 0.22% for the MilkoScan method and 0.20% for the reference method). In comparisons of the 2 methods, the highest regression coefficients were obtained with aliquots containing >3% added water. The best regression coefficients (0.85 to 1.02) were obtained fo

Read it at the source ↗

Try
Intelligent Search· scoped to this article · not medical adviceSearch the whole library →