Clinical Implementation and Validation of Automated Slice-to-Volume Reconstruction for Fetal MRI Using a Vendor-Neutral MONAI-Based Imaging Informatics Pipeline

pubmed.ncbi.nlm.nih.gov shows its articles on its own site.

Read the article on pubmed.ncbi.nlm.nih.gov ↗

Article · Aug 2026 · 1 min read

In brief

In brief

This study validates a fully automated, vendor-neutral pipeline for fetal MRI reconstruction using MONAI Deploy Express integrated with clinical PACS workflow. Among 65 examinations at a tertiary fetal center, the system achieved 90.8% acceptable brain reconstructions and demonstrated reliable operational performance for motion-corrected imaging in routine prenatal care.

Written by the GCMD Library team from the article.

Alexander J. Towbin

This study aims to evaluate the clinical performance and operational reliability of a fully automated, vendor-neutral imaging informatics pipeline for fetal MRI slice-to-volume reconstruction using open-source Medical Open Network for Artificial Intelligence (MONAI) Deploy Express, DICOM routing, and PACS return. In this retrospective implementation study, consecutive singleton fetal MRI examinations performed at a tertiary fetal care center between October and December 2025 were processed using a MONAI Deploy Express pipeline triggered by DICOM routing. The pipeline performed automated series selection and motion-corrected SVR reconstruction for fetal brain and body imaging using routine single-shot fast spin-echo inputs. Reconstructed volumes were returned to PACS for radiologist review. Three fellowship-trained fetal radiologists independently scored reconstruction quality using a 5-point Likert scale. Primary outcomes included examination-level reconstruction acceptability, inter-reader reliability, failure modes, and operational time to PACS availability after transition to the finalized production workflow. Among 67 triggered examinations, 2 represented technical workflow events and were excluded from clinical performance analysis, leaving 65 examinations for image-quality evaluation. Mean gestational age was 28.9 weeks (range, 19-36 weeks) and most fetuses had structural abnormalities. Brain SVR was rated pass-or-higher in 59/65 examinations (90.8%) and body SVR was ra

Statements in this article

  1. The automated pipeline uses MONAI Deploy Express with DICOM routing to perform slice-to-volume reconstruction for fetal MRI examinations.

    Established
  2. The pipeline performs automated series selection and motion-corrected SVR reconstruction for fetal brain and body imaging using routine single-shot fast spin-echo inputs.

    Established
  3. Reconstructed volumes are returned to PACS for radiologist review.

    Established
  4. Three fellowship-trained fetal radiologists independently scored reconstruction quality using a 5-point Likert scale.

    Established
  5. Among 67 triggered examinations, 2 represented technical workflow events and were excluded from clinical performance analysis, leaving 65 examinations for image-quality evaluation.

    Research
  6. Mean gestational age was 28.9 weeks with a range of 19-36 weeks.

    Research
  7. Brain SVR was rated pass-or-higher in 59 of 65 examinations, representing a 90.8% success rate.