Use of 5-mm Laparoscopic Stapler to Perform Open Small Bowel Anastomosis in a Neonatal Animal Model
pubmed.ncbi.nlm.nih.gov shows its articles on its own site.
Read the article on pubmed.ncbi.nlm.nih.gov ↗Article · Oct 2026 · 1 min read
In brief
In brief
This animal study compares a novel 5-mm laparoscopic stapler to traditional hand-sewn technique for neonatal small bowel anastomosis in rabbits. Stapled anastomoses were significantly faster (4 vs 16 minutes) and produced wider lumens (8.2 vs 3.7 mm), suggesting potential advantages for neonatal surgery where traditional staplers are too large.
Written by the GCMD Library team from the article.
Purpose: While adult bowel anastomoses are typically performed with staplers, neonatal small bowel anastomoses have traditionally been performed in a hand-sewn manner due to the large size of surgical staplers. The purpose of this study was to compare stapled anastomosis using a newly available, 5-mm laparoscopic stapler to a hand-sewn anastomosis in an open animal model. Methods: Twenty anastomoses were performed by two general surgery residents (10 stapled and 10 hand-sewn) in an adult New Zealand white rabbit. The small bowel was divided with a scalpel. Surgical technique was alternated between single-layer hand-sewn and stapled anastomoses. Each anastomosis was resected for ex vivo testing. Measurements collected were outer diameter of the bowel before division, time to perform the anastomosis, anastomosis inner diameter (ID), and leak test. IDs were measured by cutting the anastomosis in cross-section, taking a photograph, and measuring the diameter by computer software. In addition, the surgeons qualitatively evaluated the anastomoses for hemostasis and overall quality. Statistical significance was determined using the Student's t-test. Results: There were statistically significant differences between stapled and hand-sewn anastomosis, respectively, for average operative time (4 minutes 2 seconds versus 16 minutes 6 seconds, P < .01) and anastomosis ID (8.2 versus 3.7 mm, P < .01). There was one leak in the stapled group, which occurred at overlapping staple lines closi
Educational content from recorded physician discussions — not medical advice. Talk to your (or your child's) care team about your situation.
Article
Endoscopic Web Localization for Laparoscopic Duodenal Web Excision
Todd Ponsky · Published Oct 2026
Article
Stitch versus scar--evaluation of laparoscopic pediatric inguinal hernia repair: a pilot study in a rabbit model
Todd Ponsky · Published Oct 2026
Article
Robotic Surgery may Not "Make the Cut" in Pediatrics
Todd Ponsky · Published Oct 2026
Article
Creation of a neopylorus after pyloric exclusion using a "double-endoscope" technique
Todd Ponsky · Published Oct 2026
Article
Magnetic compression anastomosis (magnamosis) in a porcine esophagus: Proof of concept for potential application in esophageal atresia
Todd Ponsky · Published Oct 2026
Article
Single-port laparoscopy: Considerations in children
Todd Ponsky · Published Oct 2026