StayCurrentMD · The novel fetal MRI O/E CLV versus O/E LHR in predicting prognosis in congenital diaphragmatic hernias: can we teach an old dog new tricks?
Article1 min read·Published Nov 2021Older

The novel fetal MRI O/E CLV versus O/E LHR in predicting prognosis in congenital diaphragmatic hernias: can we teach an old dog new tricks?

link.springer.com shows its articles on its own site.

Read the article on link.springer.com ↗

Article · Nov 2021 · 1 min read

In brief

In brief

Study of 74 CDH patients demonstrates that fetal MRI measurement of contralateral lung volume (O/E CLV) outperforms traditional ultrasound lung-to-head ratio (O/E LHR) in predicting ECMO need and survival outcomes. O/E CLV showed superior accuracy with AUC of 0.81 vs 0.74 for ECMO prediction and 0.84 vs 0.64 for survival to discharge.

Written by the GCMD Library team from the article.

Abstract

Purpose

In congenital diaphragmatic hernia (CDH), ultrasound (U/S) measurements of the contralateral lung commonly provide the observed-to-expected lung-to-head ratio (O/E LHR) and are used to determine the severity of pulmonary hypoplasia. Fetal magnetic resonance imaging (MRI) measurement of the observed-to-expected total lung volume (O/E TLV) has been used as an adjunct to O/E LHR in predicting outcomes. Since O/E LHR only measures the contralateral lung, we sought to investigate if MRI measurements of the contralateral lung volume (O/E CLV) can accurately predict outcomes in CDH. We hypothesize that O/E CLV is a better predictor of CDH outcomes than O/E LHR.

Methods

We identified all infants with a prenatal diagnosis of CDH at our fetal center who had both MRI and U/S measurements. Using lung volume ratios of right–left 55:45, we calculated O/E CLV from O/E TLV. We used receiver-operating characteristic (ROC) curves to calculate the area under the curve (AUC) to compare the predictive accuracy of O/E CLV to O/E LHR for ECMO support, as well as survival to both discharge and 1 year.

Results

Seventy-four patients had complete prenatal imaging with 39% requiring ECMO support. The median O/E CLV was 48.0% and the median O/E LHR was 42.3%. O/E CLV was a better predictor of the need for ECMO support (AUC 0.81 vs. 0.74). O/E CLV was a better predictor of survival to discharge (AUC 0.84 vs. 0.64) and 1-year survival (AUC 0.83 vs. 0.63) than O/E LHR.

Conclusion

O/E LHR is a well-validated standard for predicting outcomes and guiding prenatal counseling in CDH. We provide evidence that fetal MRI measurements of the contralateral lung volume corrected for gestational age were more accurate in predicting the need for ECMO and survival. Future prospective studies validating O/E CLV regarding outcomes and ECMO utilization are warranted.

Level of evidence

Level III, retrospective comparative study.

Read it at the source ↗

Try
Intelligent Search· scoped to this article · not medical adviceSearch the whole library →