StayCurrentMD · The risks of postoperative complications and prolonged hospital stay in children receiving bronchoscopy
Article1 min read·Published Jun 2019Older

The risks of postoperative complications and prolonged hospital stay in children receiving bronchoscopy

jpedsurg.org shows its articles on its own site.

Read the article on jpedsurg.org ↗

Article · Jun 2019 · 1 min read

In brief

In brief

Retrospective study of 3,489 pediatric foreign body aspiration cases comparing flexible versus rigid bronchoscopy outcomes. Preoperative pulmonary disease, prolonged operative time beyond 30 minutes, and prior failed rigid bronchoscopy significantly increased risk of postoperative complications and hospital stays exceeding 2 days.

Written by the GCMD Library team from the article.

Abstract

Background

Foreign body aspiration (FBA) is a common problem among children that needs to be recognized and managed quickly. Our study aimed at comparing risk factors associated with adverse events in children receiving either flexible or rigid bronchoscopy, by reporting and analyzing our experience in the removal of airway FB primarily through flexible bronchoscopy.

Methods

A total of 3489 FBA patients were retrospectively examined. The clinical events, bronchoscopy findings, radiological findings and procedural complications were reported and analyzed.

Results

According to Fisher's exact test, preoperative cardiovascular instability, pre-operative pulmonary disease or need of lung assistance, operative time greater than 30 min, and history of ineffective rigid bronchoscopy were associated with postoperative adverse events. These same factors were also associated with prolonged hospital stay (more than 2 days). Using multivariate analysis, preoperative pulmonary disease or need of lung assistance and history of ineffective rigid bronchoscopy were associated with postoperative adverse events. These same factors were significantly associated with prolonged hospital stay.

Conclusions

Our study demonstrated that using flexible bronchoscopy to extract foreign bodies in children generally exhibits a low adverse events incidence. The risk of postoperative complications and prolonged hospital stay may significantly be higher for children with pre-operative pulmonary disease, prolonged operative time, and history of ineffective rigid bronchoscopy.

Type of study

Treatment Study.

Level of evidence

Level III.

Read it at the source ↗

Try
Intelligent Search· scoped to this article · not medical adviceSearch the whole library →